Crestron SIMPL+ Informacje Techniczne Strona 201: FAILURE (CMCVT111)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230

Crestron SIMPL™ Windows Software
ERROR (CMCVT131)
Number of Analog Signals exceeds system capacity
A given Cresnet system has certain limitations. If the compiler detects that one of
these limitations has been exceeded, one or more of these messages may be issued.
The status that comes up at the end of the compile will have the particular limitation
flagged with a “*” in front of the message.
ERROR (CMCVT132)
Required NVRAM exceeds system capacity.
A given Cresnet system has certain limitations. If the compiler detects that one of
these limitations has been exceeded, one or more of these messages may be issued.
The status that comes up at the end of the compile will have the particular limitation
flagged with a “*” in front of the message.
ERROR (CMCVT133)
Program size exceeds system capacity.
A given Cresnet system has certain limitations. If the compiler detects that one of
these limitations has been exceeded, one or more of these messages may be issued.
The status that comes up at the end of the compile will have the particular limitation
flagged with a “*” in front of the message.
NOTICE (CMCVT134)
Cannot find parameter #VAL1 for substitution in S-5 (prompt string) in Macro
S-1 (Macro File C:\cresvss\usrmacro\replacements.umc), assuming 0 (Use
quotes if this is a literal parameter).
If a parameter replacement is given but is not valid, this error occurs. For example, if
on a DELAY symbol the time is given as #VAL1 but VAL1 does not exist anywhere
on the Define Arguments symbol, this error is given when the program is compiled.
The argument to the symbol is then set to 0.
FAILURE (CMCVT135)
Could not process C:\cresvss\usrmacro\replacements.umc, macro resync
required.
If a macro was used in a program and then modified such that it's number of inputs
or outputs have changed, the compiler will see this discrepancy when it tries to load
the macro when generating the output binary file.
In order to fix this, the Re-Synch Macros in Program option must be selected from
SIMPL Windows. It is possible that more inputs or outputs will be added to the
symbol, in which case the macro will now be incomplete. It is also possible that
inputs or outputs will be deleted from the symbol.
Note that ANY time macros are changed, the program using them should be
resynched. If signal types are changed on a macro, the compiler will not catch this.
Installation & Operations Guide – DOC. 5728C Crestron SIMPL Windows • 191