Crestron SIMPL+ Informacje Techniczne Strona 156: Isolated Network Connection
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230

Software Crestron SIMPL™ Windows
146 • Crestron SIMPL Windows Installation & Operations Guide – DOC. 5728C
Crestron e-Control SDK
The Crestron e-Control SDK is a separately purchased Software Development Kit
(SDK) that enables computers to behave like Crestron touchpanels. These "virtual"
touchpanels can consist of HTML pages viewed in a browser (WebControl) or may
be a stand-alone application written in a language such as Visual Basic or Visual
C++ (ActiveCNX). The SDK provides the necessary Java and ActiveX components,
the CNX Gateway software (which allows the computer to communicate with
Crestron hardware over Ethernet), and full documentation for their use.
When working with the SDK, you must add "virtual touchpanel" definitions to the
corresponding SIMPL Windows program in order to enable communications
between the control system and computers connected to the CNX Gateway, just as
you add a VT-3500 definition to your program whenever you program a system
using "physical" touchpanels.
In the SIMPL Windows Configuration Manager, open the device folder marked
"Ethernet Control Modules," and drag-n-drop the "Virtual Touchpanel" device onto
the DPA card or the Ethernet Units arrow. Double click on the icon to set the IP ID
and the corresponding IP address. The IP address is the address of the computer
running the CNX Gateway (to which additional computers may be connected). In the
Program Manager, program the Virtual Touchpanel device exactly as you would
program an actual touchpanel. See the documentation (PDF format) that comes with
the Crestron e-Control SDK for more information.
Ethernet Connection Information
Recommended Connection
CNX control systems and CEN network modules can be connected directly onto an
Intranet with static IP addresses and subnet masks assigned by the System
Administrator. The "gateway address" is the address of the Intranet's existing router.
An inexpensive Ethernet hub may be used to provide physical connections.
Isolated Network Connection
This method is for connecting devices directly to the PC without connecting to a
larger Intranet. It can be used when valid IP addresses have not yet been assigned
and should be used for brief testing purposes only, because multiple Ethernet devices
may see only the PC, and not each other.
Connect all CNX devices to an Ethernet hub, as well as the PC. Disconnect the hub's
connection to the Intranet. To conform with TCP/IP standards, you should set all
devices to an IP address of 192.168.2.x (where x can range from 1 to 254), as these
addresses have been set aside expressly for testing purposes. Set the ARP (Address
Resolution Protocol) table on your PC so it knows how to route the packets:
Bring up an MS-DOS prompt (Windows 95/98) or a Command Prompt (Windows
NT) and type:
arp -s <ip-address> <MAC-address>
for each device that the PC should see.