Crestron SIMPL+ Informacje Techniczne Strona 195: Compiler Errors Defined
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230

Crestron SIMPL™ Windows Software
Compiler Errors Defined
ERROR (CMCVT101)
This program has no signals – cannot create
C:\ANYDEALER\SIMPL\MYJOB\A12345.BIN
For a program to do something useful, it must have at least one signal defined. A
program with no signals can’t do anything and therefore the compiler cannot produce
a valid binary file.
WARNING (CMCVT102)
Signal “SIGNAL_NAME” has no driving source.
Cresnet programming is like a schematic, and all wires on a schematic should have a
source point and a destination point. A signal without destination is like a wire that’s
run to a chip but has no point of origin. Often such an error is due to misspelling a
signal name while connecting it between gates.
NOTICE (CMCVT103)
Signal “SIGNAL NAME” has no destination.
Cresnet programming is like a schematic, and all wires on a schematic should have a
source point and a destination point. A signal without a destination is like a wire
that’s run from a chip but goes nowhere. Often such an error is due to misspelling a
signal name while connecting it between gates. Often a programmer may attach a
signal to the output of a gate if a particular output is considered mandatory, but this
signal is never used. On logic gates (not macros), a programmer can put a 0 on an
output that is considered mandatory if they are not using that output. Such an
example would be on an RMV in which the programmer does not want to use the
OUT line but they do want to use the [OUT*] line.
NOTICE (CMCVT104)
Cannot open C:\ANYDEALER\SIMPL\MYJOB\A12345.BIN
The output binary file cannot be opened for write. Generally this happens if another
application currently has the file open for write or there is no disk space left.
NOTICE (CMCVT105)
End Of String encountered before a complete hex constant was specified in S-3,
Prompt "string".
A valid hex constant is specified as a \ followed by an X or x followed by 2
hexadecimal characters (0-9, A-F). If a hex constant is specified but not completed,
as in the above example, then this message is generated. The error message that tells
you what symbol the error was encountered in (S-3) and the particular prompt on the
symbol where the error occurred (“string”).
Installation & Operations Guide – DOC. 5728C Crestron SIMPL Windows • 185
Plik PDF · ·
Pytania o Crestron SIMPL+