Crestron SIMPL+ Informacje Techniczne Strona 143: Network Analyzer Analysis
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230

Crestron SIMPL™ Windows Software
Network Analyzer Graphs
Voltage (V)
The graphs displayed by Network Analyzer display voltage level from -5V to 10V on the Y axis
Time (ms)
The time sample runs from 0 to 6.55ms. along the X axis.
Labels
The blue "Y" represents the wire labeled "Y" in a cresnet network.
The red "Z" represents the wire labeled "Z" in a cresnet network.
Background
Colors
The gray area of the graph represents when the control processor (rack) is commanding the network.
The white area of the graph represents when the net device that was requested is in control of the
network.
Network Analyzer Analysis
Network Analyzer offers an analysis of the graphs it displays. A brief note is listed in
the bottton right corner of the graph box. If no problems are found, the analysis is
boxed in green. Problems are boxed in red and a detailed explanation is available.
Anaysis displays "No Problems Found" in Green
Analysis displays a brief warning in Red.
To view a comprehensive analysis, click on the button.
"Delta Y on transmit is too small"
Description
The difference between the maximum voltage on the Y line and the minimum
voltage on the Y line must be > 1.88 volts during transmit.
Possible Cause
This problem can be caused by a faulty network driver in the control system or by a
short circuit between the Y line and either power or ground in the network wiring.
To verify if this problem is due to a faulty network driver, disconnect all network
wires from your control system and repeat the test. If you receive this message again,
you have a problem with your control system. If not, there is a probable short circuit
in your network wiring.
"Delta Z on transmit is too small"
Description
The difference between the maximum voltage on the Z line and the minimum
voltage on the Z line must be > 1.88 volts during transmit.
Possible Cause
This problem can be caused by a faulty network driver in the control system or by a
Installation & Operations Guide – DOC. 5728C Crestron SIMPL Windows • 133