FlipTop Touch Screen Control System Crestron FT-TSC600
14 FlipTop Touch Screen Control System: FT-TSC600 Operations & Installation Guide DOC. 7593A
Connectors, Controls, and Indicators (Continued)
# CONNECTORS
1
,
CONTROLS, AND
INDICATORS
DESCRIPTION
6 PWR LED (1) Dual color LED;
Yellow indicates operating power supplied
via PoE;
Green indicates device is ready
7 HW-R Button (1) Recessed miniature push button for
hardware reset
8 SW-R Button
Pressing this in combination with
HW-R
button performs a system restart without
loading the program. Pressing it alone
momentarily while the system is running
restarts the program
9 LAN PoE
3
Pin 8
Pin 1
(1) 8-pin RJ-45 with two LED indicators;
10BASE-T/100BASE-TX Ethernet port;
Power over Ethernet compliant;
Green LED indicates link status;
Yellow LED indicates Ethernet activity
PIN
DESCRIPTION
1
TX +
2
TX -
3
RX +
4
DC +
5
DC +
6
RX -
7
DC -
8
DC -
10 G (Ground)
(1) 6-32 screw, chassis ground lug