Crestron TPMC-10-DSW Docking Assembly for TPMC-10
NOTE: When daisy-chaining Cresnet units, strip the ends of the wires carefully to
avoid nicking the conductors. Twist together the ends of the wires that share a pin on
the network connector, and tin the twisted connection. Apply solder only to the ends
of the twisted wires. Avoid tinning too far up the wires or the end becomes brittle.
Insert the tinned connection into the Cresnet connector and tighten the retaining
screw. Repeat the procedure for the other three conductors.
NOTE: For larger networks (i.e., greater than 28 network devices), it may become
necessary to add a Cresnet Hub/Repeater (CNXHUB) to maintain signal quality
throughout the network. Also, for networks with lengthy cable runs, it may be
necessary to add a Hub/Repeater after only 20 devices.
Identity Code
Every equipment and user interface within a Cresnet network requires a unique
identity code (Net ID). These codes are two-digit hexadecimal numbers from 03 to
FE. The Net ID of each unit must match an ID code specified in the SIMPL
Windows program. Refer to “Setting the Net ID in Device Settings Window” on
page 10 for details of the SIMPL Windows procedure. The Net ID of the
TPMC-10-DSW is factory set to 22. The Net IDs of multiple TPMC-10-DSWs in the
same system must be unique and changed from a personal computer (PC) via the
Crestron Toolbox software program.
NOTE: For detailed information on establishing communication between the PC
and control system, refer to the latest version of the 2-Series Control System
Reference Guide (Doc. 6256), which is available from the Crestron website
(http://www.crestron.com/manuals).
Complete the following steps to change the Net ID.
1. Open the Crestron Toolbox.
2. From the Toolbox menu, select Tools | Network Device Tree. Select
the address of the control system from the Address Book at the lower
left of the "Network Device Tree" window.
3. The TPMC-10-DSW should appear in the network device tree. Click
the ‘+’ next to the TPMC-10-DSW to expand it.
4. Right click on the Net ID and select Change Network ID. The Net ID
will become highlighted.
5. Enter a new valid Cresnet ID (between 03 and FE) and press Enter.
6. A confirmation message will appear as shown in the following graphic.
Click on OK to accept the change.
7. Repeat this procedure for each TPMC-10-DSW to be added to the
system.
Operations and Installation Guide - DOC. 6400 Docking Assembly for TPMC-10: TPMC-10-DSW 5