Crestron CT-3000 Dokumentacja Strona 16

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 94
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 15
Crestron e-control Database Manager SW-DBM
16 Server Configuration In Depth Installation & Reference Guide — DOC. 5823
Reply from 132.149.2.2: bytes=32 time=8ms TTL=60
Reply from 132.149.2.2: bytes=32 time=5ms TTL=60
Reply from 132.149.2.2: bytes=32 time=5ms TTL=60
Reply from 132.149.2.2: bytes=32 time=5ms TTL=60
Once a reliable connection is established, test that the CNX control system is
listening and responding properly. Reconfigure Viewport communications to use
TCP/IP by selecting Setup | Communications Settings. Once the Port Settings
window opens, select TCP/IP as the Connection Type. For IP Address, Click on
Fixed and enter the CNX control system IP address in the active field. Test the new
connection by issuing the Diagnostics | Check Operating System Version
command.
Additional Server Side Setup
In addition to properly setting up and testing communications with each connected
system, the following steps are also required to make the server operational:
1. Select database file. Supply the full pathname to the database under the
COM Settings tab. This file is the sole source of all database tables accessed
by all signal blocks. See “The Database File,” page 32, for additional
information.
The demos are pre-configured to point to the file DBMdemo.mdb in the demos
folder.
2. Indicate control system connection. Point each active signal block to a COM
Settings definition. (If you have not yet defined the connection through which
this signal block will communicate, you can leave this blank for the now.
However, the signal block cannot be activated until it references a COM
Settings definition.) See “COM Settings,” page 23, for a description of how to
point a signal block to a COM Settings definition.
All the signal blocks in the demo configuration already point to a COM Settings
definition.
Server Configuration In Depth
This section is a reference to all the options available in the Configuration Options
window. Changes to options in this window are saved to the current Configuration
Settings file when the OK or the Apply buttons are actuated. Therefore, it is
important to make sure you are operating on the appropriate Configuration Settings
file before opening the window.
Specifying a Configuration File
The installer registers the file demoDBM.ini as the current Configuration
Settings file. This file pre-configures the server for all three demos, and particularly
for use with the Quick Start Guide — which instructs you to load demo1.
You can use the File | Configuration file… command to select a Configuration
Settings file of your choice. The file pathname so specified is stored in the Windows
registry on your machine. In addition to specifying the configuration filename, this
command also instantly reconfigures the server based on the named file. This is a
very useful feature for the developer working on multiple projects.
NOTE: If the server cannot open a specified configuration file, it uses default values for all options.
If any changes are made, a new config file is created using the specified pathname when the OK or
the Apply buttons are actuated
Przeglądanie stron 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 93 94

Komentarze do niniejszej Instrukcji

Brak uwag

Krystal Touch of NY DL3609BPRI manuals

Owner’s manuals and user’s guides for Unknown Krystal Touch of NY DL3609BPRI.
We providing 1 pdf manuals Krystal Touch of NY DL3609BPRI for download free by document types: Installation Guide


Table of contents





More products and manuals for Unknown Krystal Touch of NY

Models Document Type
DL3798ABPAS Installation Guide   Krystal Touch of NY DL3798ABPAS Installation Guide, 1 pages
DL3606CPAS Installation Guide   Krystal Touch of NY DL3606CPAS Installation Guide, 1 pages
DL3608ABPRI Installation Guide   Krystal Touch of NY DL3608ABPRI Installation Guide, 1 pages
DL3660BPRI Installation Guide   Krystal Touch of NY DL3660BPRI Installation Guide, 1 pages
DL3797CPAS Installation Guide   Krystal Touch of NY DL3797CPAS Installation Guide, 1 pages
DL3615CPAS Installation Guide   Krystal Touch of NY DL3615CPAS Installation Guide, 1 pages
DL3612CPRI Installation Guide   Krystal Touch of NY DL3612CPRI Installation Guide, 1 pages
DL3800CPRI Installation Guide   Krystal Touch of NY DL3800CPRI Installation Guide, 1 pages
DL3798BPRI Installation Guide   Krystal Touch of NY DL3798BPRI Installation Guide, 1 pages
DL3611ABPAS Installation Guide   Krystal Touch of NY DL3611ABPAS Installation Guide, 1 pages
DL3733ABPRI Installation Guide   Krystal Touch of NY DL3733ABPRI Installation Guide, 1 pages
DL3607BPRI Installation Guide   Krystal Touch of NY DL3607BPRI Installation Guide, 1 pages
DL3797CPRI Installation Guide   Krystal Touch of NY DL3797CPRI Installation Guide, 1 pages
DL3660BPA Installation Guide   Krystal Touch of NY DL3660BPA Installation Guide, 1 pages
DL3608BPRI Installation Guide   Krystal Touch of NY DL3608BPRI Installation Guide, 1 pages
DL3608CPAS Installation Guide   Krystal Touch of NY DL3608CPAS Installation Guide, 1 pages
DL3606BPAS Installation Guide   Krystal Touch of NY DL3606BPAS Installation Guide, 1 pages
DL3605BPAS Installation Guide   Krystal Touch of NY DL3605BPAS Installation Guide, 1 pages
DL3609BPAS Installation Guide   Krystal Touch of NY DL3609BPAS Installation Guide, 1 pages
DL3733CPRI Installation Guide   Krystal Touch of NY DL3733CPRI Installation Guide, 1 pages