Proper grounding is required. Connect the ground from the QM transmitter
(QM-FTCC) to earth ground. Connect the Cresnet shield at the
QM-RMCRX-BA to the chassis ground provided on the QM-RMCRX-BA. The
QM-RMCRX-BA chassis must also be connected to an earth ground (building
steel). Refer to the following grounding diagram.
Ground Wire Connections
NOTE: Do not connect the shield to earth ground at the QM-FTCC.